Background. It is noted that patients with xerostomia after sialometry may notice a decrease in xerostomia.

Aim. To study the effect of stimulated sialometry on the quantitative parameters of salivation, to explain the mechanism and reason for such an effect.

Material and methods. Controlled dynamic parotid sialometry was performed in 22 patients with xerostomia. Saliva was taken with a Lashley capsule (n=44) and a catheter (n=44), stimulated with 1% pilocarpine solution. At the 1st stage, the capsule was on the right, the catheter was on the left, a week later (2nd stage) the catheter was on the right, the capsule was on the left. The amount of saliva (ml) obtained with a capsule was taken as a control indicator, with a catheter — as a test indicator, the difference between them determined the rheological state of saliva. The study was approved by the ethical committee. The analysis of indicators in dynamics was carried out separately in the group with a capsule, separately in the group with a catheter. Significance of differences was assessed using Student's t-test. The results were considered significant at p ≤0.05.

Results. By the 2nd stage of the study, the sialometry values (ml) obtained using the capsule increased in 13 (69.1%) cases, did not change (n=2; 9.1%) or decreased (n=7; 31.8%) in 9 (40.9%) cases. By the 2nd stage of the study, sialometry values (ml) obtained using a catheter increased in 16 (72.7%) cases, did not change (n=2; 9.1%) or decreased (n=4; 18.2%) in 6 (27.3%) cases. The number of cases with increased secretion was significantly higher than other cases (t=3.385; p <0.001). The dynamics of the rheological state was as follows. A week later, in 7 (31.8%) cases, the indicators of the rheological state of saliva (the difference between the control and test sialometry values of 0.5 ml or more) returned to normal (the difference between the control and test sialometry values of 0.5 ml or less), in 2 (9.1%) cases, the norm was not achieved (t=1.947; p <0.05). Thus, sialometry in the short term can positively influence the secretory function of the salivary glands. However, parasympathetic stimulation of secretory function depletes the number of secretory granules in glandulocytes, which limits the effect of pilocarpine in reducing xerostomia.

Conclusion. Simultaneous sampling of saliva from the parotid glands with a Lashley capsule (control) and a catheter as a capillary viscometer makes it possible to determine the rheological properties of saliva; the improvement in the rheological properties of saliva after stimulated sialometry is associated with the use of the m-cholinomimetic pilocarpine.

Full Text

Restricted Access

About the authors

Alexander V. Shchipskiy

Moscow State University of Medicine and Dentistry named after A.I. Yevdokimov

Author for correspondence.
Email: sialocenter@mail.ru
ORCID iD: 0000-0002-2851-0171

M.D., D. Sci. (Med.), Prof., Depart. of Maxillofacial Surgery and Traumatology

Russian Federation, Moscow, Russia

Marina M. Kalimatova

Moscow State University of Medicine and Dentistry named after A.I. Yevdokimov

Email: dockalimatova@mail.ru
ORCID iD: 0000-0002-0935-8936

PhD Stud., Depart. of Maxillofacial Surgery and Traumatology

Russian Federation, Moscow, Russia

Pavel N. Mukhin

Moscow State University of Medicine and Dentistry named after A.I. Yevdokimov

Email: panistom@mail.ru
ORCID iD: 0000-0002-8311-5529

M.D., Cand. Sci. (Med.), Assist. Prof., Depart. of Maxillofacial Surgery and Traumatology

Russian Federation, Moscow, Russia

References

  1. Shchipskiy AV. Xerostomia, hyposalivation and impaired excretory (evacuation) function of the salivary glands (review). Parodontologiya. 2002;(3):45–50. (In Russ.)
  2. Simonova MV, Radenska-Lopovok SG. Porazhenie slyunnykh zhelyoz pri sindrome i bolezni Shyogrena. Diagnoz. Differencial'nyy diagnoz. Prakticheskie rekomendatsii dlya vrachey-stomatologov. (Damage to the salivary glands in Sjogren's syndrome and disease. Diagnosis. Differential diagnosis. Practical recommendations for dentists.) Nasono-va VA, editor. Moscow: PC STS; 2010. 153 р. (In Russ.)
  3. Gomes PD, Juodzbalys G, Fernandes MH, Guobis Z. Diagnostic Approaches to Sjögren’s Syndrome: a Literature Review and Own Clinical Experience. J Oral Maxillofac Res. 2012;3(1):e3. doi: 10.5037/jomr.2012.3103.
  4. Romacheva IF, Yudin LA, Afanasyev VV, Morozov AN. Zabolevaniya i povrezhdeniya slyunnykh zhelyoz. (Diseases and injuries of the salivary glands.) Moscow: Meditsina; 1987. 238 р. (In Russ.)
  5. Afanasyev VV, Mirzakulova UR. Slyunnye zhelezy. Bolezni i travmy. Rukovodstvo dlya vrachey. (Salivary glands. Diseases and injuries. A guide for doctors.) Moscow: GEOTAR-Media; 2019. 315 р. (In Russ.)
  6. Vavilova TP, Yanushevich OO, Ostrovskaya IG. Slyuna. Analiticheskie vozmozhnosti i perspektivy. (Saliva. Analytical opportunities and prospects.) Moscow: BINOM; 2014. 312 р. (In Russ.)
  7. Komarova KV, Ratkina NN. Prevalence of xerostomia among the patients stomatological ambulatory. Fundamentalnyye issledovaniya. 2014;(2):82–84. (In Russ.)
  8. Andreeva TB. Experience in studying the function of the human salivary glands. Stomatologiya. 1965;(2):39–43. (In Russ.)
  9. Kalk WW, Vissink A, Spijkervet FK, Bootsma H, Kallenberg CG, Nieuw Amerongen AV. Sialometry and sialohemistry: Diagnostic tools in Sjögren's syndrome. Ann Rheum Dis. 2001;60(12):1110–1116. doi: 10.1136/ard.60.12.1110.
  10. Kalk WW, Vissink A, Stegenga B, Bootsma H, Nieuw Amerongen AV, Kallenberg CGM. Sialometry and sialochemistry: A non-invasive approach for diagnosing Sjögren’s syndrome. Ann Rheum Dis. 2002;61(2):137–144. doi: 10.1136/ard.61.2.137.

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Рис. 1. Схема и основные характеристики капсулы Лешли, используемой для проведения контролируемой динамической сиалометрии

Download (17KB)
3. Рис. 2. Схема и основные характеристики полиэтиленового катетера, используемого для проведения контролируемой динамической сиалометрии

Download (13KB)

© 2022 Eco-Vector





This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies